LBL-2807A-130

 1. Max. thrust :4598g 

 2. MTBF:600hours 

 3. Motor Maintenance:Regularly lubricate bearings to reduce friction and wear 

” LIBERAL LBL” motors are an ultra-light zero gravity for Multi-rotor motor.

High-Qualityimported Materials; High Slot Space Factor On Winding For Longer, Clearer And More Stable Flight.

1.Scope of application

This product manual is applicable to models LBL-2807A-1300 DC brushless motors

2.Operating condition and Motor type

No. Items Specification Remarks
2-1 Rated voltage(V) 25V DC
2-2 Operating voltage range 19.8~26.4V DC
2-3 Motor type 3-phases 14-poles
2-4  Number of stator slots 12 Slots
2-5 Stator Winding
2-6 Winding insulation class Class H Temperature resistance of 180 ℃
2-7 Operating ambient temperature (℃)/humidity (%) -20℃~+40℃/5%~85%
2-8 Storage environment temperature(℃)/humidity (%) -20℃~+60℃/5%~85% No condensation on motor and packaging(Avoid storing the product in a high temperature and high humidity environment. If The storage time  should not exceed 6 months in a normal temperature and humidity environment)
2-9 Rotation direction Under the same test conditions of the motor, the direction of the output shaft is visually observed, and the rotation of motor is clockwise/counterclockwise Using our company’s testing system
2-10

 

Appearance No mechanical damage marks, no corrosion marks, the surface is clean and free of dirt, the color conforms to the  standard swatch, etc. Visual inspection (the inspection standard is based on the appearance limit template)
2-11 Measuring condition

 

Measure all normal temperature and humidity if there is any doubt about judgement, measurements shall be made within 20±30C, 65±20%RH
2-12 Test method Observe rated current.rated speed and rated input power after operating for 1 min

 

3.Electrical  characteristics

 

3-1 No load rated voltage (V) 10V DC  

Brushless  comprehensive tester (without load)

3-2 No load speed (rpm) 13000±10%
3-3 No load current (A) 1.5A Max
3-4 Terminal resistance 0.056Ω(reference value) Terminal to terminal resistance
3-5 Terminal inductance TBD Inductance between terminals at 1V/1KHZ (minimum)
3-6 Insulation resistance 10MΩ Min AT 100V DC between motor terminal and metal housing
3-7 Load rated voltage (V) 25V DC The data on the left is only representative values (testing conditions: use our testing system and use

1050R three blade propeller)

3-8 Room temperature (0℃~30℃)  load current (A) 46.1(reference value)
3-9 Maximum output lift (g) 2530(reference value)
3-10 Maximum power (W) 1152(reference value)

 

 

 

 

4.mechanical properties

4-1 Motor weight (g) 55.9±0.5g Test conditions: Electronic scale (accuracy: 0.01g)
4-2 Dimension Refer to the CAD drawing see picture 1

(Motor outline assembly drawing)

 

5.reliability test

No. Items Test setup Criteria
5-1 Aging test Test voltage:25V DC

Load:Half throttle test

Test conditions:JC life test fixture unit

Test content:The service life of the half throttle test motor is greater than 300 hours. After aging, the test motor can operate normally, and the current, speed, and resistance comply with the provisions of this technical specification

After the experiment, the motor was allowed to stand for 2 hours in a normal temperature and humidity environment, and the experimental motor was tested to comply with the regulations of 6-1
 

5-2

High temperature test  

 

 

Test temperature:60℃

Test time:72H

Test content:Adjust the high and low temperature laboratory temperature to the severe level +60 ℃, run the motor under no-load condition, and check whether the motor meets the judgment standard. After adjusting the speed to 0, power on for 72 hours, and test the no-load data

 

After the experiment, the motor was allowed to stand for 2 hours in a normal temperature and humidity environment, and the experimental motor was tested to comply with the regulations of 6-1
 

5-3

 

Low temperature test

Test temperature:-20℃

Test time:48H

Test content:Adjust the temperature of the high and low temperature laboratory to the severe level of -20°C, run the motor under no-load condition, and check whether the motor meets the judgment standard. After adjusting the speed to 0, power on for 48 hours, and test the no-load data

5-4  

High temperature and high humidity storage test

Test temperature:40℃

Test humidity:85%RH

Test time:2d

Test content:The motor should be able to withstand a temperature of 60°C, a relative humidity of 85%, a constant damp heat test that lasted 2 days, and the insulation resistance should be measured immediately after the test, which should not be less than 1MΩ. The motor should have no obvious deterioration of appearance quality and works normally . After 12 hours of recovery under normal atmospheric conditions, the motor should be able to work normally.

5-5 Salt spray test experimental condition:

1:试The temperature of the test chamber is required to be (35 ± 2) ℃, the humidity is more than 95%, the mist reduction is 1-2ml / (H · cm2), and the nozzle pressure is 78.5-137.3kpa (0.8-1.4kgf / cm2).

2:((5 ± 0.5)% sodium chloride, pH 6.5-7.2

Experimental time:24h (continuous spray)

There is no obvious rust on the external surface of the motor after the test.
5-6 Vibration test Frequency: 10~55Hz

Amplitude: 1.2mm

Frequency 1cot/min: 1.5H in each direction of the X, Y, and Z axes

After the experiment, the motor was allowed to stand for 2 hours in a normal temperature and humidity environment, and the experimental motor was tested to comply with the regulations of 6-1

 

6.Requirements

NO.  Requirements
 

6-1

 Speed: initial value ± 20%

电Current: initial value ± 20%

Insulation resistance: meets the initial value

 